Application code | E+
|
Type version | mk1
|
Lamp type | TL5/PL-L
|
Number of lamps | 2
piece/unit
|
Number of products on MCB (16 A type B) (nom.) | 9
|
Automatic restart | Yes
|
Input Voltage | 220 to 240
V
|
Input frequency | 50 to 60
Hz
|
Operating frequency (max.) | -
kHz
|
Operating frequency (min.) | -
kHz
|
Ignition method | Warm Start
|
Crest factor (max.) | 1.7
|
Power factor 100% load (nom.) | 0.95
|
Ignition time (max.) | 0.2
s
|
Mains voltage performance (AC) | -8%-+6%
|
Mains voltage safety (AC) | -10%-+10%
|
Earth leakage current (max.) | 0.5
mA
|
Inrush current width | 0.35
ms
|
Standby power consumption (max.) | 0.25
W
|
Ballast factor (nom.) | 1.0
|
Power losses (nom.) | 11.3
W
|
Inrush current peak (max.) | 35
A
|
Connector type input terminals | WAGO 251 universal connector
[ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Cable capacity output wires mutual (max.) | 150
pF
|
Connector type output terminals | WAGO 251 universal connector
[ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Connector type control input terminals | WAGO 251 universal connector
[ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Wire strip length | 8.0-9.0
mm
|
Dual fixture master/slave | -
[ not specified] |
Control input terminal cross section | 0.50-1.00
mm²
|
Input terminal cross section | 0.50-1.00
mm²
|
Output terminal cross section | 0.50-1.00
mm²
|
Auto-insert (ALF/ADS) wire cross section | 0.5
mm²
|
Cable capacity output wires to earth (max.) | 150
pF
|
Rated ballast-lamp power | 80 W
|
T-ambient (max.) | 50
°C
|
T-ambient (min.) | 15
°C
|
T storage (max.) | 80
°C
|
T storage (min.) | -40
°C
|
T case lifetime (max.) | 75
°C
|
T-Case maximum (max.) | 75
°C
|
Stable lamp operation temperature | Not Specified
|
T-Ignition (max.) | 50
°C
|
T-Ignition (min.) | 0
°C
|
Control interface | TD
|
Regulating level power | 1%-100%
|
Control input protection | Yes (Basic insulation)
|
Housing | L 425x30x21
|
Battery voltage lamp ignition | 220
V
|
Battery voltage lamp operation | 154-276
|
Energy efficiency index | A1
|
|||
IP classification | IP 20
[ Ingress Protection 20] |
|||
EMI 9 kHz ... 30 MHz | EN55015
|
|||
EMI 30 MHz ... 1,000 MHz | EN55022 level B
|
|||
Safety standard | IEC 61347-2-3
|
|||
Performance standard | IEC 60929
|
|||
Quality standard | ISO 9000:2000
|
|||
Environmental standard | ISO 14001
|
|||
Harmonic current emission standard | IEC 61000-3-2
|
|||
EMC immunity standard | IEC 61547
|
|||
Vibration standard | IEC68-2-6 F c
|
|||
Bumps standard | IEC 68-2-29 Eb
|
|||
Humidity standard | EN 61347-2-3 clause 11
|
|||
Approval marks | EMC
|
CE marking
|
ENEC certificate
|
CCC certificate
|
Temperature marking | Yes
|
|||
Emergency standard | IEC 60598-2-22
|
|||
Humming and noise level | 30 dB(A)
|
Full product code | 871150091067730
|
Order product name | HF-Ri TD 280 TL5/PL-L E+ 220-240V
|
EAN/UPC – product | 8711500910677
|
Order code | 91067730
|
Numerator – quantity per pack | 1
|
SAP numerator – packs per outer box | 12
|
Material no. (12 NC) | 913700609666
|
Net Weight (Piece) | 0.417
kg
|