Application code | E+
|
Type version | -
|
Lamp type | PL-T/C
|
Number of lamps | 2
piece/unit
|
Number of products on MCB (16 A type B) (nom.) | 12
|
Automatic restart | Yes
|
Input Voltage | 195-240
V
|
Input frequency | 50 to 60
Hz
|
Ignition method | Warm Start
|
Crest factor (max.) | 1.7
|
Power factor 100% load (nom.) | 0.95
|
Ignition time (max.) | 1
s
|
Mains voltage performance (AC) | -8%-+6%
|
Mains voltage safety (AC) | -10%-+10%
|
Earth leakage current (max.) | 0.5
mA
|
Inrush current width | 0.35
ms
|
Standby power consumption (max.) | 0.27
W
|
Ballast factor (nom.) | 1
|
Power losses (nom.) | 2.7
W
|
Inrush current peak (max.) | 45
A
|
Efficiency at full load [%] | 90.88
%
|
Connector type input terminals | WAGO 250 series
|
Cable capacity output wires mutual (max.) | 150
pF
|
Connector type output terminals | WAGO 250 series
|
Connector type control input terminals | WAGO 250 series
|
Wire strip length | 8.0-9.0
mm
|
Dual fixture master/slave | Yes
[ Master/Slave operation possible] |
Control input terminal cross section | 0.50-1.50
mm²
|
Input terminal cross section | 0.50-1.50
mm²
|
Output terminal cross section | 0.50-1.50
mm²
|
Auto-insert (ALF/ADS) wire cross section | 0.50-1.50
mm²
|
Cable capacity output wires to earth (max.) | 150
pF
|
Rated ballast-lamp power | 26-42 W
|
Rated lamp power on PL-T/C | 26
W
|
Rated lamp power on PL-T | 32/42
W
|
Rated lamp power on TL5C | 22/40/22+40
W
|
System power on PL-T/C | 58.5
W
|
System power on PL-T | 69/89.2
W
|
System power on TL5C | 52.5/84.1/68.3
W
|
Power loss on PL-T/C | 6.5
W
|
Power loss on PL-T | 7/7.2
W
|
Power loss on TL5C | 6.5/7.1/6.8
W
|
Lamp power on TL5C | 46/77/61
W
|
Lamp power on PL-T | 62/82
W
|
Lamp power on PL-T/C | 50
W
|
T-ambient (max.) | 50
°C
|
T-ambient (min.) | -25
°C
|
T storage (max.) | 80
°C
|
T storage (min.) | -40
°C
|
T case lifetime (max.) | 75
°C
|
T-Case maximum (max.) | 75
°C
|
T-Ignition (max.) | 50
°C
|
T-Ignition (min.) | -25
°C
|
Control interface | TD
|
Regulating level power | 3%-100%
|
Control input protection | Yes (Basic insulation)
|
Housing | L 123x79x33
|
Energy efficiency index | A1 BAT
|
|||
IP classification | IP 20
[ Ingress Protection 20] |
|||
EMI 9 kHz ... 30 MHz | EN55015
|
|||
EMI 30 MHz ... 1,000 MHz | EN 55022 Class B
|
|||
Safety standard | IEC 61347-2-3
|
|||
Performance standard | IEC 60929
|
|||
Quality standard | ISO 9000:2000
|
|||
Environmental standard | ISO 14001
|
|||
Harmonic current emission standard | IEC 61000-3-2
|
|||
EMC immunity standard | IEC 61547
|
|||
Vibration standard | IEC68-2-6 F c
|
|||
Bumps standard | IEC 68-2-29 Eb
|
|||
Humidity standard | EN 61347-2-3 clause 11
|
|||
Approval marks | EMC
|
CE marking
|
ENEC certificate
|
CCC certificate
|
Temperature marking | Yes
|
|||
Emergency standard | IEC 60598-2-22
|
|||
Humming and noise level | Inaudible
|
Full product code | 871829124169000
|
Order product name | HF-Ri TD 2 26-42 PL-T/C E+
|
EAN/UPC – product | 8718291241690
|
Order code | 24169000
|
SAP numerator – quantity per pack | 1
|
Numerator – packs per outer box | 12
|
SAP material | 913700684866
|
Net Weight (Piece) | 0.230
kg
|