Application code | HE II
|
Type version | -
|
Lamp type | TL5
|
Number of lamps | 2
piece/unit
|
Number of products on MCB (16 A type B) (nom.) | 28
|
Automatic restart | Yes
|
Input Voltage | 220 to 240
V
|
Input frequency | 50 to 60
Hz
|
Operating frequency (nom.) | 45
kHz
|
Crest factor (nom.) | 1.7
|
Power factor 100% load (nom.) | 0.99
|
Preheat time | 0.5
s
|
Mains voltage performance (AC) | 202-254V-8%-+6%
|
Mains voltage safety (AC) | 198-264V-10%-+10%
|
Earth leakage current (max.) | 0.5
mA
|
Inrush current width | 0.25
ms
|
Ballast factor (nom.) | 1
|
Power losses (nom.) | 2.0-5.5
W
|
Inrush current peak (max.) | 24
A
|
Efficiency at full load [%] | 93.3
%
|
Connector type input terminals | WAGO 744 connector
|
Cable capacity output wires mutual (max.) | 200
pF
|
Connector type output terminals | WAGO 744 connector
[ Suitable for manual wiring] |
Cable length hot-wiring | 0.75
m
|
Wire strip length | 8.0-9.0
mm
|
Dual fixture master/slave | Possible, lamp wires 2m max. length
[ Master/Slave operation possible] |
Input terminal cross section | 0.50-1.00
mm²
|
Output terminal cross section | 0.50-1.00
mm²
|
Cable capacity cold output wires – earth (max.) | 200
pF
|
Cable capacity hot output wires – earth (max.) | 200
pF
|
Rated ballast-lamp power | 14-35 W
|
Rated lamp power on TL5 HE | 14/35
W
|
System power on TL5 HE | 30.5/76.5
W
|
Lamp power on TL5 HE | 28.5/71.0
W
|
Power loss on TL5 HE | 2.0/5.5
W
|
T-ambient (max.) | 55
°C
|
T-ambient (min.) | -20
°C
|
T storage (max.) | 50
°C
|
T storage (min.) | -40
°C
|
T-case lifetime (nom.) | 75
°C
|
T-Case maximum (max.) | 75
°C
|
Housing | L360x30x22
|
Nominal light output after 60 seconds | 100% of EBLF
|
Normal operating voltage (DC) | 220-240
V
|
Battery voltage guaranteed operation | 176-275
V
|
Battery voltage guaranteed ignition | 186-275
V
|
Emergency ballast lumen factor (EBLF) (nom.) | 100
%
|
Nominal light output after 5 seconds | 50% of EBLF
|
Energy efficiency index | A2 BAT
|
||||||
IP classification | IP 20
[ Ingress Protection 20] |
||||||
EMI 9 kHz ... 30 MHz | EN55015
|
||||||
Vibration standard | IEC68-2-6 F c
|
||||||
Bumps standard | IEC 68-2-29 Eb
|
||||||
Approval marks | CE marking
|
ENEC certificate
|
CCC certificate
|
C-Tick certificate
|
TISI marking
|
SIRIM approval
|
CCC certificate
|
Humming and noise level | 30 dB(A)
|
Full product code | 871829175844000
|
Order product name | HF-S 2 14-35 TL5 HE II 220-240V
|
EAN/UPC – product | 8718291758440
|
Order code | 75844000
|
SAP numerator – quantity per pack | 1
|
Local code description | HF-S 214-35 TL5 II 220-240V 50/60Hz
|
Numerator – packs per outer box | 12
|
SAP material | 913713042166
|
Net Weight (Piece) | 0.245
kg
|