Application code | EII
|
Type version | mk1
|
Lamp type | TL5
|
Number of lamps | 2
piece/unit
|
Number of products on MCB (16 A type B) (nom.) | 12
|
Automatic restart | Yes
|
Input Voltage | 220 to 240
V
|
Input frequency | 50 to 60
Hz
|
Ignition method | Warm Start
|
Crest factor (max.) | 1.7
|
Ignition time (max.) | 5.0
s
|
Mains voltage performance (AC) | -8%-+6%
|
Mains voltage safety (AC) | -10%-+10%
|
Earth leakage current (max.) | 0.5
mA
|
Inrush current width | 0.35
ms
|
Constant wattage deviation | -2%/+2%
|
Ballast factor (nom.) | 1.00
|
Power losses (nom.) | 6.1-8.9
W
|
Inrush current peak (max.) | 31
A
|
Efficiency at full load [%] | 94.89
%
|
Connector type input terminals | Insert
|
Cable capacity output wires mutual (nom.) | 70
pF
|
Connector type output terminals | Insert
|
Cable length hot-wiring | 0.75
m
|
Wire strip length | 8.0-9.0
mm
|
Input terminal cross section | 0.50-1.00
mm²
|
Output terminal cross section | 0.50-1.00
mm²
|
Cable capacity output wires to earth (nom.) | 70
pF
|
Rated ballast-lamp power | 28-54 W
|
Rated lamp power on TL5 | 28/35/49/54
W
|
System power on TL5 | 33.6/41.1/53/53.2
W
|
Lamp power on TL5 | 27.5/34.4/45.6/48.4
W
|
Power loss on TL5 | 6.1/6.7/7.4/8
W
|
T-ambient (max.) | 50
°C
|
T-ambient (min.) | -25
°C
|
T storage (max.) | 80
°C
|
T storage (min.) | -40
°C
|
T-case lifetime (nom.) | 75
°C
|
T-Case maximum (max.) | 75
°C
|
T-Ignition (max.) | 50
°C
|
T-Ignition (min.) | -25
°C
|
Housing | L360x30x22
|
Nominal light output after 60 seconds | 100% of EBLF
|
Battery voltage lamp operation | 198-276
|
Emergency ballast lumen factor (EBLF) (nom.) | 100
%
|
Nominal light output after 5 seconds | 50% of EBLF
|
Energy efficiency index | A2 BAT
|
||
IP classification | IP 20
[ Ingress Protection 20] |
||
EMI 9 kHz ... 30 MHz | EN55015
|
||
EMI 30 MHz ... 1,000 MHz | EN 55022 Class B
|
||
Safety standard | IEC 61347-2-3
|
||
Performance standard | IEC 60929
|
||
Quality standard | ISO 9000:2000
|
||
Environmental standard | ISO 14001
|
||
Harmonic current emission standard | IEC 61000-3-2
|
||
EMC immunity standard | IEC 61547
|
||
Vibration standard | IEC68-2-6 F c
|
||
Bumps standard | IEC 68-2-29 Eb
|
||
Humidity standard | EN 61347-2-3 clause 11
|
||
Approval marks | CE marking
|
ENEC certificate
|
VDE-EMV certificate
|
Temperature marking | Yes
|
||
Emergency standard | IEC 60598-2-22
|
||
Humming and noise level | Inaudible
|
Full product code | 871150091502330
|
Order product name | HF-Pi 2 28/35/49/54 TL5 EII 220-240V
|
EAN/UPC – product | 8711500915023
|
Order code | 91502330
|
SAP numerator – quantity per pack | 1
|
Numerator – packs per outer box | 12
|
SAP material | 913700624366
|
Net Weight (Piece) | 0.305
kg
|