Type version | mk1
|
Lamp type | PL-T/C
|
Number of lamps | 1
piece/unit
|
Number of products on MCB (16 A type B) (nom.) | 20
|
Automatic restart | No
|
Input Voltage | 220 to 240
V
|
Input frequency | 50 to 60
Hz
|
Operating frequency (nom.) | 20-40
kHz
|
Crest factor (nom.) | 1.9
|
Power factor 100% load (nom.) | 0.95
|
Mains voltage safety (AC) | -10%-+10%
|
Earth leakage current (nom.) | 0.5
mA
|
Connector type input terminals | 250 manual connector
[ Suitable for manual wiring and easy release button] |
Cable capacity output wires mutual (max.) | 120
pF
|
Colour input terminals | Orange
|
Colour output terminals | Grey
|
Connector type output terminals | 250 manual connector
[ Suitable for manual wiring and easy release button] |
Cable length hot-wiring | 0.75
m
|
Wire strip length | 9.0-10.0
mm
|
Dual fixture master/slave | Not advisable
[ Master/Slave operation not advised] |
Input terminal cross section | 0.50-1.50
mm²
|
Output terminal cross section | 0.50-1.50
mm²
|
Cable capacity output wires to earth (max.) | 120
pF
|
Rated ballast-lamp power | 13 W
|
System power on PL-T/C | 15
W
|
Power loss on PL-T/C | 2.0
W
|
Lamp power on PL-T/C | 13.0
W
|
T-case lifetime (nom.) | 65
°C
|
T-Case maximum (max.) | 65
°C
|
Battery voltage lamp ignition | 165-253
V
|
Energy efficiency index | A2
|
|
IP classification | IP 20
[ Ingress Protection 20] |
|
Overvoltage protection 276 VAC | 48
h
|
|
EMI 9 kHz ... 30 MHz | EN55015
|
|
Vibration standard | IEC68-2-6 F c
|
|
Bumps standard | IEC 68-2-29 Eb
|
|
Humidity standard | EN61347-I
|
|
Approval marks | CCC certificate
|
CB Certificate
|
Full product code | 872790083286000
|
Order product name | EB-C 113 PL-T/C 220-240V 50/60Hz
|
EAN/UPC – product | 8711500997722
|
Order code | 83286000
|
SAP numerator – quantity per pack | 1
|
Numerator – packs per outer box | 24
|
SAP material | 913713198414
|
Net Weight (Piece) | 0.101
kg
|